+49 431 5 80 80-11
Power supply 10 - 32 V DC
Power consumption (typical) 0.5 W
Measuring principle Fluorescence measurement
Evaluation (300 - 400 nm)
Measuring range (typical) 0 - 30 / 100 / 300 ppm
Measuring accuracy 3 % FS
Detection limit (typical) 0.1 ppm
Measuring interval ? 1 s
Light source < 300 nm
Material Stainless steel 1.4404 / Titanium [optional]
Operation temperature range 0 °C to +55 °C
Weight
0.8 kg
DimensionsLength 150 mm; Ø 38 mm
Interface Modbus [RTU]
Maximum pressure 6 bar
Art. no.461 6200
Technical data
Parameters
? BTEX
? PAH
? Refined oil in water
Application Areas
Environmental Monitoring
? River water
? Surface water
Wastewater
? E?luent monitoring
? Trend analysis
? Early detection of discharge
Process Measurement & Control Technology
? Process monitoring in industrial facilities
? Control of process water treatment
? Process optimization
Drinking Water
? Quality control
? Alarm systems
The BlueTrace Oil in Water Sensor is a compact
fluorescence probe for the measurement of BTEX, PAH
and refined oil in water. The robust design of the Blue-
Trace Sensor allows for applications in harsh condi-
tions, such as corrosive media or at high pressure.
BlueTrace Oil in Water Sensor
Main Functions & Features
Selectable Measuring Range
Robust & Non-corrosive Modbus Interface Compact Design Easy Calibration Low Power Demand
Insensitive to Ambiant Light High Pressure Resistance