ONLINE GAS AND LIQUID ANALYZER EXPERTS
WWW.CHROMATOTEC.COM
vigi e-n o se *
Online analysis and monitoring of odorous compounds
Sulfur & VOC monitoring
TSP V10
GAS ANALYZER GC 866
Chromatotec ® is specialized in VOC, Sulfur and permanent gases analysis at trace and ultra trace levels (%, ppm, ppb, ppt). Please visit our website for more details. Updated: April 2021
* Analytical solution for vigiODOR platform
Model: V20022
(rack version)
Model: V10022
(wall mounted version
with gas generators)
On-line applications:
Fence line
Odor control monitoring
Deodorisation process
Fugitive emission
Process control / CIP
Targetted compounds:
Standard version: H2S / SO2 / MM / EM / DMS / DMDS / DES / Total VOC
Upon request: TBM / NPM / MES / 2BM / IBM / NBM / THT / IPM
Main markets:
WWTP / Refineries / Petrochemicals / Gas process sites / Rendering plaints
Ambiant / Industrial air monitoring
Odor impact management
TRS measurement
Standards:
ISO 19739:2004, DIN 51855/7
ASTM D 7493-08
Correlation with EN13 725 / ASTM 679-E04
H 2S
SO 2
Total
Reduced
Sulfur
Mercaptans
tVOC
Sulfides
Odor
Index
Odor Unit
(OUE/m
3)
WWW.CHROMATOTEC.COM
To contact us: sales@chromatotec.com
Chromatotec ® is continuously improving its products, therefore these specifications are subject to change without notice
NORTH AMERICAHouston - USA EUROPEBordeaux - FRANCE ASIA Beijing - CHINA
Description :
The vigi e-nose is the first analyzer able to track VOC & Sulfurs at ppb/
ppt levels. It is more sensitive than human nose. It is composed by one
autoGC-ED (MEDOR® Electrochemical wet cell Detector) and PID for
VOCs. Zero air generator included in the same box for autonomous
operation.
Principle:
• Automatic sampling using a loop linked to sampling pump
• Automatic loop injection on metallic capillary column
• Isothermal gas chromatograph
• Detection of all compounds eluting from the column performed by
MEDOR® Detector: Electrochemical wet cell Detector which is SSD
Sulfur Specific Detector.
• Signal provided by reaction between the wet cell electrolyte and the
sulfur compounds
• PID dedicated for total VOC measurement.
Key points:
• Automatic calibration/validation of the data, with embeded permeation
tube for sulfurs. No span gases required.
• Continuous monitoring with automatic online sampling
• Analytical performances:
• Specific, linear and very sensitive to sulfur compounds
• Results validation by automatic standard injection
• Long term stability using detector installed in reservoir
• Extremely low maintenance
• Very long life time detector with electrolyte, up to 10 years
• Low gas consumption, can be reduced in option
• More than 10 years data storage
• No cylinders required thanks to internal calibration tube and gas
generators
• Automatic control with process device
• Intelligents system with tunable and interactive alarm levels
• PID detector in addition to MEDOR® detector
• Powerful VISTACHROM Chromatotec ® software: • Remote monitoring & injection control• Full traceability with on board archiving of results and chromato - grams• QC Set up and control of threshold alarms• Data export by MODBUS / 4-20 mA / 0-10 V• Time stamp results
vigi e-n o se *
Online analysis and monitoring of odorous compounds
Sulfur & VOC monitoring
Options:
• Multiple stream selector (up to 16 streams with one analyser)
• Portable olfactometer or lab olfactometer (EN 13725)
• Modeling software with weather station for live odor/chemical impact
• Complaints management with platform for automatic integration of per -
ception of neighborhood
• Explosion proof version Exp or Exd for ATEX, IECEx zone 1 and 2 and
also for CSA C1D2
• Calculation modules (Average / Statistics / Odor unit OU e/m3 and more)
• Automatic data transfert through: Module for 4 outputs 4-20mA / Modbus
RTU or TCP IP
• 24 V DC power supply
• Electric selection valve to reduce air consumption
• Wall mounted box
• Nitrogen generator when standard used for calibration is different from
DMS
• Vigiodor: dispersion modeling software for odor impact
Technical Specifications:
Total VOC with PID detector
Sulfur compounds analysis:
• Speciation and Total Reduced Sulfur by sum (TRS): H2S,
SO2, DMS, MM, DES, DMDS, EM compounds
Detection limits*:
• Sulfur detector: less than 1 ppb for H2S• TVOC PID detector: less than 10 ppb on DMS• 50 UO E/m 3 (limit of the olfactometer) • *more sensitive analyzers available upon request with special application
Range (adjustable depending on application):
• 0/10 or 0/100 or 0/1000 (ppb or ppm) • Calculation : Odor Index, TVOC, Total Sulfur, (OU e/m3
with XXXOU)
Relative Standard Deviation for sulfur detector:
• RSD < 3 % on concentration over 48H• RSD < 0.5% on retention time over 48H
Relative Standard Deviation for PID:
• < 1% on concentration at 100ppb over 24h
Cycle Time for the following different analyses: • H2S, SO2, MM, EM, DMS, DMDS, DES 600s• With special application following compounds can be added : IPM, TBM, NPM, 2BM, IBM, NBM, MES and THT 1200s
Supervisor:
• Embeded computer Windows ® based with LCD display
• 128 GB of Hardware storage on SSD memory
Communication:
• Ethernet, remote control
Gas supply:
• Carrier: Dry air or N2 (3 bars): ? 4 ml/min.• CALIB: in continuous ~ 50 ml / min.• CALIB during validation ~ 250ml/min for M52 configuration• Pneumatic valve 90ml/commutation
• Sampling dryer: 150 to 200 ml/min
Power supply:
• Main: 230V 60Hz or 115V / 50Hz
Electrical consumption:
• 150 VA
Dimensions and weights:
Wall mounted box : • Height: 1440 mm • Width: 600mm• Depth: 300 mm• Net weight: From 45 to 70 Kg
To order:
vigi e-nose (rack version)
vigi e-nose (wall mounted version)
NH 3 analyzer associated (upon request) D27000
NH 3 sensor associated (upon request) XXXNH3
Model:
V20022
V10022
Rack: 19’’ (5U)• Height: 222 mm • Width: 482mm• Depth: 660 mm• Net weight: 22 Kg