TSP V10
ONLINE GAS ANALYZER EXPERTS
gas analyzer gc 866
- Model: V10022 (wall mounted version)
- Model: V20022 (rack version)
on-line applications
- Fence line
- Odor control monitoring
- Deodorisation process
- Fugitive emission
- Process control / CIP
Targetted compounds: Standard version: H2S / SO2 / MM / EM / DMS / DMDS / DES / Total VOC. Upon request: TBM / NPM / MES / 2BM / IBM / NBM / THT / IPM
Main markets: WWTP / Refineries / Petrochemicals / Gas process sites / Rendering plains
standards
ISO 19739:2004, DIN 51855/7, ASTM D 7493-08, Correlation with EN13 725 / ASTM 679-E04
vigi e-nose*
Online analysis and monitoring of odorous compounds, Sulfur & VOC monitoring
description
The vigi e-nose is the first analyzer able to track VOC & Sulfurs at ppb/ppt levels. It is more sensitive than the human nose. It is composed of one autoGC-ED (MEDOR® Electrochemical wet cell Detector) and PID for VOCs. Zero air generator included for autonomous operation.
principle
- Automatic sampling using a loop linked to sampling pump
- Automatic loop injection on metallic capillary column
- Isothermal gas chromatograph
- Detection of all compounds eluting from the column performed by MEDOR® Detector: Electrochemical wet cell Detector which is SSD Sulfur Specific Detector.
- Signal provided by reaction between the wet cell electrolyte and the sulfur compounds
- PID dedicated to total VOC measurement.
key points
- Automatic calibration/validation of the data, with embedded permeation tube for sulfurs
- Continuous monitoring with automatic online sampling
- Analytical performances: Specific, linear, and very sensitive to sulfur compounds
- Results validation by automatic standard injection
- Long-term stability using detector installed in reservoir
- Extremely low maintenance
- Very long lifetime detector with electrolyte, up to 10 years
- Low gas consumption, can be reduced in option
- More than 10 years data storage
- No cylinders required thanks to internal calibration tube and gas generators
- Automatic control with process device
- Intelligent system with tunable and interactive alarm levels
- PID detector in addition to MEDOR® detector
- Powerful VISTACHROM Chromatotec® software: Remote monitoring & injection control, Full traceability with onboard archiving of results and chromatograms, QC Set up and control of threshold alarms, Data export by MODBUS / 4-20 mA / 0-10 V, Time stamp results
options
- Multiple stream selector (up to 16 streams with one analyzer)
- Portable olfactometer or lab olfactometer (EN 13725)
- Modeling software with weather station for live odor/chemical impact
- Complaints management with platform for automatic integration of perception of neighborhood
- Explosion-proof version Exp or Exd for ATEX, IECEx zone 1 and 2 and also for CSA C1D2
- Calculation modules (Average / Statistics / Odor unit OU e/m3 and more)
- Automatic data transfer through: Module for 4 outputs 4-20mA / Modbus RTU or TCP IP
- 24 V DC power supply
- Electric selection valve to reduce air consumption
- Wall mounted box
- Nitrogen generator when standard used for calibration is different from DMS
- VigiODOR: dispersion modeling software for odor impact