Document
tsp_µ-BTEX-001_microBTEX
Contenu du document
ONLINE GAS AND LIQUID ANALYZER EXPERTS
WWW.CHROMATOTEC.COM
microBTEX
Accurate, portable & user friendly BTEX analyzer
µ-BTEX-001
Chromatotec® is specialised in VOC, Sulfur and permanent gases analys\
is at trace and ultra trace levels (ppm, ppb, ppt). Please visit our website for more details.
Updated: July 2021
Model : µ-BTEX-001
Benzene
Ethylbenzene
Toluene
Xylenes
Applications
Public buildings occupational exposure verification
Industrial hygiene measurement
Chambers tests studies
Material emissions quantification
Building management
Concentration levels continuous monitoring
Standards
IEC/EN 61010-1:2010
EMC: NF EN 61326-1:2013
WWW.CHROMATOTEC.COM
microBTEX
Accurate, portable & user friendly BTEX analyzer
To contact us: sales@chromatotec.com
Chromatotec ® is continuously improving its products, therefore these specifications are subject to change without notice
NORTH AMERICAHouston - USA EUROPEBordeaux - FRANCE
ASIA Beijing - CHINA
Product technical specifications
Detection limit
• Benzene & Toluene: ~ 1 ppb• Ethylbenzene & m+p-Xylenes: ~ 2 ppb (with default
settings) / o-Xylene: ~ 4 ppb
Detection range • 0 - 1000 ppb
Measurement
• Detector : PID• Temporal resolution 0.1 seconds• Response time : One measurement every 10 minutes
(with default settings)• Analysis condition : Gas T°: 5 - 40°C; Gas RH: 20 - 80%; Atmospheric pressure• Calibration : Gaseous BTEX mixture or gaseous Toluene
Sampling • Method : loop of 200?L• Gas flow rate : Few 10 to few 100 mL min -1
• Carrier gas : Nitrogen 1 - 4 bar (default setting 4 bar/ 2.5 mL min -1)
• Supply connection : 1/8’’
Instrument supply • Power supply : Input 100 - 240V ±10%; 1.5 A max; 47 -
63 Hz - Output 15V; 6.67A 100W• Battery life : Lithium-Ion / Autonomy > 4h (2x12 volt)• Power consumption : max 75 w
General
• Dimensions : 32×28×15 cm; 6.0 kg
• Operational conditions : 0 - 40°C / 20 - 80% RH
• Storage conditions : -20°C - +40°C / 0 - 85% RH
• Display : 7” TFT display; resolution 800 x 480; integrated
touchscreen
Software & communication
• Embedded software: Expert and standard modes; Data
saving; Analysis setting, launching and monitoring;
Defects and maintenance management.
• USB : Data transfer (aera, retention time, concentration)• Ethernet : Communication and remote control
Mobility and accessories • Carrier case with handle and integrated pre-cut foam for
accessories• Power supply & cable; Particle filter; Filter strainer; Carrier case with pre-cut foam; 1/8’’ inox caps with associated fer - rules; Analysis column; 58L Nitrogen bottle with adapted manometer; Teflon tube and associated ferrules for carrier gas; Spanner (10 - 11 mm); Stylus.
Other feature
• Comptability : Canister & FLEC® system
Principle
microBTEX is a compact BTEX analyzer which allows continuous and
real-time qualification and quantification of Benzene, Toluene, Ethyl -
benzene and Xylene.
• Field portable
• Easy to use
• Labour saving
• Accuracy
• Highly sensitive
• Real time monitoring
• Continous monitoring
• Smart embedded software
Advantages
User friendly
• Compact size and low weight
• Deployment in less than 5 minutes
• Powered by mains or battery
• Low consumption of carrier gas
• Rapid calibration with gaseous BTEX mixture or only Toluene
• Compatibilty with canisters and FLEC® System
Rapid & accurate measurements
• Short time of analysis: 10 minutes
• Detection limit lower than 1 ppb for benzene
Analysis programmation, monitoring & data logging
• Color touch screen with standard/expert users modes
• Sequence programmation
• Results in near real-time
• Data logging for quality control
Issued from French academic research
• Innovation from CNRS & Strasbourg University
• Patented microfluidic device
• Supported by EU and innovation programs
Options:
• Sampling Teflon line (OD: 1/8’’; L: 150 cm); Printed manual
• Model PID in standard for BTEX and in option for VOC like
methanol ETO, THT...
• Model TCD in option for H2, O2, N2, CO, CO2, CH4...
To order:Micro BTEX
Model: µ-BTEX-001
Entreprise(s) concernée(s) :
Produit(s) concerné(s) :
Date d'upload du document :
lundi 12 juillet 2021