brochure sur l'analyseur portable microBTEX µ-BTEX-001
présentation de l'analyseur portable microBTEX pour BTEX

Contenu du document
µ-BTEX-001
ONLINE GAS AND LIQUID ANALYZER EXPERTS
microBTEX: Accurate, portable & user friendly BTEX analyzer
Applications
- Public buildings occupational exposure verification
- Industrial hygiene measurement
- Chambers tests studies
- Material emissions quantification
- Building management
- Concentration levels continuous monitoring
Standards
- IEC/EN 61010-1:2010
- EMC: NF EN 61326-1:2013
Chromatotec® is specialised in VOC, Sulfur and permanent gases analysis at trace and ultra trace levels (ppm, ppb, ppt). Please visit our website for more details.
Updated: July 2021
MicroBTEX is a compact BTEX analyzer which allows continuous and real-time qualification and quantification of Benzene, Toluene, Ethylbenzene, and Xylene. It is field portable, easy to use, labour-saving, highly sensitive, and provides real-time continuous monitoring with smart embedded software.
Advantages
- User friendly
- Compact size and low weight
- Deployment in less than 5 minutes
- Powered by mains or battery
- Low consumption of carrier gas
- Rapid calibration with gaseous BTEX mixture or only Toluene
- Compatibility with canisters and FLEC® System
Rapid & accurate measurements
- Short time of analysis: 10 minutes
- Detection limit lower than 1 ppb for benzene
Analysis, programmation, monitoring & data logging
- Color touch screen with standard/expert users modes
- Sequence programmation
- Results in near real-time
- Data logging for quality control
Issued from French academic research
- Innovation from CNRS & Strasbourg University
- Patented microfluidic device
- Supported by EU and innovation programs
Product technical specifications
- Detection limit: Benzene & Toluene: ~ 1 ppb, Ethylbenzene & m+p-Xylenes: ~ 2 ppb (with default settings) / o-Xylene: ~ 4 ppb
- Detection range: 0 - 1000 ppb
- Measurement: Detector : PID, Temporal resolution 0.1 seconds, Response time : One measurement every 10 minutes (with default settings), Analysis condition: Gas T°: 5 - 40°C; Gas RH: 20 - 80%; Atmospheric pressure, Calibration: Gaseous BTEX mixture or gaseous Toluene
Sampling
- Method: loop of 200?L
- Gas flow rate: Few 10 to few 100 mL min-1
- Carrier gas: Nitrogen 1 - 4 bar (default setting 4 bar/ 2.5 mL min-1)
- Supply connection: 1/8’’
Instrument supply
- Power supply: Input 100 - 240V ±10%; 1.5 A max; 47 - 63 Hz - Output 15V; 6.67A 100W
- Battery life: Lithium-Ion / Autonomy > 4h (2x12 volt)
- Power consumption: max 75 w
General
- Dimensions: 32×28×15 cm; 6.0 kg
- Operational conditions: 0 - 40°C / 20 - 80% RH
- Storage conditions: -20°C - +40°C / 0 - 85% RH
- Display: 7” TFT display; resolution 800 x 480; integrated touchscreen
Software & communication
- Embedded software: Expert and standard modes; Data saving; Analysis setting, launching and monitoring; Defects and maintenance management.
- USB: Data transfer (area, retention time, concentration)
- Ethernet: Communication and remote control
Mobility and accessories
- Carrier case with handle and integrated pre-cut foam for accessories
Options
- Sampling Teflon line (OD: 1/8’’; L: 150 cm); Printed manual
- Model PID in standard for BTEX and in option for VOC like methanol ETO, THT...
- Model TCD in option for H2, O2, N2, CO, CO2, CH4...
Other feature
- Compatibility: Canister & FLEC® system
Chromatotec® is continuously improving its products, therefore these specifications are subject to change without notice.
To contact us: sales@chromatotec.com
Contact
- NORTH AMERICA: Houston - USA
- EUROPE: Bordeaux - FRANCE
- ASIA: Beijing - CHINA
Visit www.chromatotec.com for more details.