brochure de l'analyseur de gaz en ligne TRSMEDOR M51/M52
brochure sur l'analyseur de gaz TRSMEDOR pour composés sulfurés

Contenu du document
TSP M51 / M52
Online Gas Analyzer Experts
GAS ANALYZER GC 866: TRSMEDOR®
S2
ppm (M51) or ppb (M52)
Online analysis and monitoring of odorous sulfur compounds
- Model Options:
- Rack version: M52022
- Wall mounted version: M52022
- Applications:
- Odor Index
- Fence line
- Fermentation process
- Deodorisation process
- Fugitive emission
- Targetted Compounds:
- Standard Version: H2S, SO2, MM, EM, DMS, DMDS, DES
- Upon Request: IPM, TBM, NPM, MES, 2BM, IBM, NBM, THT
- Main Markets:
- WWTP
- Refineries
- Petrochemicals
- Gas process sites
- Ambient/Industrial air monitoring
- Odor impact management
- TRS measurement
- Standards:
- ISO 19739:2004, DIN 51855/7
- ASTM D 7493-08
- Certification: GOST, ATEX, IECEx, CSA, CSA international
Chromatotec® est spécialisé dans l'analyse des COV, du soufre et des gaz permanents à des niveaux de trace et ultra trace (%, ppm, ppb, ppt).
Updated: October 2018
Visit our website: WWW.CHROMATOTEC.COM
TRSMEDOR®
ppm (M51) or ppb (M52)
Online analysis and monitoring of odorous sulfur compounds
Description:
The TRSMEDOR® is an autoGC-ED (MEDOR® Electrochemical wet cell Detector) for the analysis and monitoring of sulfur compounds in air: H2S, Mercaptans, Sulfides.
- Two versions exist according to levels of concentration expected:
- The TRSMEDOR® ppm
- The TRSMEDOR® ppb
Principle:
- Automatic sampling using a loop linked to sampling pump
- Automatic loop injection on metallic capillary column
- Isothermal gas chromatograph
- Detection of all compounds eluting from the column performed by MEDOR® Detector: Electrochemical wet cell Detector which is SSD Sulfur Specific Detector.
- Signal provided by reaction between the wet cell electrolyte and the sulfur compounds
Key Points:
- Automatic calibration/validation of the data, with embedded permeation tube
- Continuous monitoring with automatic online sampling
- Analytical performances:
- Specific, linear and very sensitive to sulfur compounds
- Results validation by automatic standard injection
- Long term stability using detector installed in reservoir
- Extremely low maintenance
- Very long life time detector with electrolyte, up to 10 years
- Low gas consumption, can be reduced in option
- More than 10 years data storage
- No cylinders required thanks to internal calibration tube and gas generators
- Automatic control with process device
- Intelligent system with tunable and interactive alarm levels
- Powerful VISTACHROM Chromatotec® software:
- Remote monitoring & injection control
- Full traceability with on board archiving of results and chromatograms
- QC Set up and control of threshold alarms
- Data export by MODBUS / 4-20 mA / 0-10 V
- Time stamp results
Options:
- Multiple stream selector (up to 16 streams with one analyser)
- Modeling software with weather station for live odor/chemical impact
- Explosion proof version Exp or Exd for ATEX, IECEx zone 1 and 2 and also for CSA C1D2
- Calculation modules (Average / Statistics / Odor unit OU e/m³ and more)
- Automatic data transfer through: Module for 4 outputs 4-20mA / Modbus RTU or TCP IP / MGS1
- Nitrogen or air generator
- 24 V DC power supply
- Electric selection valve to reduce air consumption
- Wall mounted box XXX934
Chromatotec® est en constante amélioration de ses produits, ces spécifications sont donc susceptibles d'être modifiées sans préavis.
Contact: sales@chromatotec.com
Regions:
- North America: Houston - USA
- Europe: Bordeaux - FRANCE
- Asia: Beijing - CHINA
Visit our website: WWW.CHROMATOTEC.COM