Document
tsp_m41_m42_energyMEDOR
Contenu du document
ONLINE GAS ANALYZER EXPERTS
WWW.CHROMATOTEC.COM
GAS ANALYZER GC 866
TSP M41 / TSP M42
energyMED O R ®
ppm (M41) or ppb (M42)
Online analysis and monitoring of sulfur compounds in natural gas
and gaseous fuels
Chromatotec ® is specialized in VOC, Sulfur and permanent gases analysis down to ultra trace levels (%, ppm, ppb, ppt). Please visit our website for more details
Main applications:
Impurities detection in Natural Gas / LPG / Propane / Butane Deodorisation control ppb Propellant gas Catalyzer protection
Natural gas or LPG odorisation control ppm
Targetted compounds:
In standard : THT / H 2S / DMS / Mercaptans: MM / EM / IPM / TBM /NPM/ MES
In option: 2 BM / IBM / NBM
Main markets:
PetrochemicalGas transportation Process Fiscal metering station
Standard:
ASTM D7493-08, ISO 19739:2004, DIN 51855/7
Certifications:
GOST
Updated: February 2021
Bu-SH
H 2S
Odorants
DMS
THT
TBM
Et-SH
DMDS
Model: M41022 Model: M41022 - Atex - 21 - Exd
WWW.CHROMATOTEC.COM
To contact us: sales@chromatotec.com
NORTH AMERICAHouston - USA EUROPEBordeaux - FRANCE
ASIA Beijing - China
Chromatotec ® is continuously improving its products, therefore these specifications are subject to change without notice
energyMED O R ®
ppm (M41) or ppb (M42)
Online analysis and monitoring of sulfur compounds
in natural gas and gaseous fuels
Model:M41022
M42022M41022-ATEX-Z2M41022-ATEX-Z1M41022-ATEX-Z1-Exd
Description :
The energyMEDOR ® is an autoGC-ED (MEDOR® Electrochemical wet
cell Detector) for the analysis and monitoring of sulfur compounds in
natural gas and gaseous fuels: H 2S, Mercaptans, Sulfides.
Two versions exist:
• The energyMEDOR ® ppm (which measures at ppm levels)
• The energyMEDOR ® ppb (which measures at ppb levels).
Principle:
• Automatic sampling using a loop
• Automatic loop injection on metallic capillary column
• Isothermal gas chromatograph
• Detection of all compounds eluting from the column performed by
MEDOR® Detector:Electrochemical wet cell Detector which is SSD
Sulfur Specific Detector.
• Signal provided by electrochemical reaction between the wet cell elec -
trolyte and the sulfur compounds
Key points:
• Fully compliant with ASTM D 7493-08 : Standard Test Method for On -
line Measurement of Sulfur Compounds in Natural Gas and Gaseous
Fuels by Gas Chromatograph and Electrochemical Detection
• Continuous monitoring with automatic online sampling
• Analytical performances:
• Specific, linear and very sensitive to sulfur compounds
• Results validation by automatic standard injection
• Long term stability using wet cell detector installed in reservoir
• Extremely low maintenance
• Very long life time detector with electrolyte, up to 10 years
• Low gas consumption, can be reduced in option
• More than 10 years data storage
• No cylinders required thanks to internal calibration tube
• Automatic control with process device
• Intelligence system with tunable and interactive alarms levels
• Powerfull VISTACHROM Chromatotec ® software: • Remote monitoring & injection control• Full traceability with on board archiving of results and chromato - grams• QC Set up and control of threshold alarms• Data export by MODBUS / 4-20 mA / 0-10 V• Time stamp results
Technical specifications:
Detection limits: • energyMEDOR ® ppm: H2S: 0.1 ppm (0.1417 mg/m 3), mercaptans: 0.1 ppm • energyMEDOR ® ppb: H2S: 5 ppb (7.0 µg/m 3), mercaptans: 5 ppb
Range (adjustable depending on application): • 0/10 or 0/100 or 0/1000 (ppb or ppm)
Relative Standard Deviation: • RSD < 3 %: on concentration over 48 h• RSD < 0.5 %: on retention time over 48 h
Cycle Time for the following different analysis: • H2S/ MM / EM 300 s • H2S, mercaptans 1,THT 720 s • H2S, mercaptans 1,THT
• H2S, mercaptans2,THT 1200 s
Supervisor: • Embedded computer Windows ® based with LCD display • 32 GB of Hardware storage on SSD memory
Linearity: • > 0.995 for all compounds
Communication: • MODBUS protocol included in standard
Gas supply: • Carrier: Dry air or N2 (3 bar): < 4 ml/min • Use N 2 if THT is present • Internal calibration: 50 ml/min for ppm range• Sample inlet 1 bar• Pneumatic valve 90 ml/commutation
Power supply: • Main: 230 V / 115 V or 50/60 Hz
Electrical consumption: • Average: 150 VA
Dimensions and weight: • Rack: 19" (5U) • Height: 222 mm• Width: 482 mm• Depth: 660 mm• Net Weight: 22 Kg
1 MM / EM / IPM / TBM / NPM / MES and Total BM if no THT2 MM / EM / IPM / TBM / NPM / 2 BM / IBM / NBM / THT
To order : energyMEDOR ® ppm / inbuilt computer energyMEDOR ® ppb with CALIB / inbuilt computer energyMEDOR Exp Atex zone 2 energyMEDOR Exp Atex zone 1 energyMEDOR® Exd Atex zone1
Available options:
• Explosion proof version Exp or Exd for Atex IECEx zone 1 and 2 group
IIC T4 and also for CSA C1D2 group B , C & D T4
• Internal calibration and validation system with permeation tube
• Multiple stream selector (up to 16 streams with one analyzer)
• Calculation modules (Average / Statistics / Odor index...)
• Automatic data transfert through: Module for 4 outputs 4-20mA (with
0 mA for instrument default / 0-10 V / Modbus RTU or TCP IP
• Electric selection valve to reduce air consumption
• 24 V DC power supply
• Nitrogen generator for safe or hazardous area
900 s with CALIB for validation of each analysis
• Exd version• Height: 1900 mm • Width: 800 mm• Depth: 600 mm• Net weight: 105 kg
Entreprise(s) concernée(s) :
Produit(s) concerné(s) :
Date d'upload du document :
lundi 22 mars 2021