ONLINE GAS ANALYZER EXPERTS
WWW.CHROMATOTEC.COM
THT M ED O R ®
Online analysis & control of gas odorisation
TSP M31
Chromatotec ® is specialised in VOC, Sulfur and permanent gases analysis at trace and ultra trace levels (ppm, ppb, ppt). Please visit our website for more details.
GAS ANALYZER GC 866
Updated: February 2021
Model: M31022 Model: M31022-ATEX-Z1
THT M EDOR ® applications:
Odorisation processes:
Continuous monitoring of THT levels in natural gas
Automatic THT injection level control
User definable alarm thresholds
Multiple stream analysis (Upstream / downstream)
Deodorisation processes:
ppb level analysis (Detection limit: 5 ppb THT)
Automatic alarm generation
Catalyser protection
Standard:
ASTM D7493-14, ISO 19739:2004, DIN 51855/7
Certifications:
GOST, ATEX, IECEx, CSA, CSA international
ASTM D7493-14 : Standard Test Method for Online Measurement of Sulfur Compounds in
Natural Gas and Gaseous Fuels by Gas Chromatograph and Electrochemical D\
etection
THT
TBM
WWW.CHROMATOTEC.COM
To contact us: sales@chromatotec.com
Chromatotec ® is continuously improving its products, therefore these specifications are subject to change without notice
THT M ED O R ®
Online analysis & control of gas odorisation
NORTH AMERICAHouston - USA EUROPEBordeaux- FRANCE
ASIABeijing - CHINA
Description:
• THT MEDOR® is an autoGC-ED (MEDOR® Electrochemical wet cell Detector) for the analysis and monitoring of THT and TBM in natural gas and gaseous fuels.
Principle:
• Automatic sampling using a loop
• Automatic loop injection on packed column
• Isothermal gas chromatograph
• Detection of THT and TBM eluting from the column performed by MEDOR®
Detector:Electrochemical wet cell Detector which is SSD Sulfur Specific Detec -
tor.
• Signal provided by reaction between the wet cell electrolyte and the sulfur
compounds
KeyPoints:
• Fully compliant with ASTM D 7493-14 : Standard Test Method for Online
Measurement of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas
Chromatograph and Electrochemical Detection.
• Automatic calibration/validation of the data, with embeded permeation tube
• Continuous monitoring with automatic online sampling
• Analytical performances:
Specific, linear and very sensitive to sulfur compounds
Results validation by automatic standard injection
Long term stability using detector installed in reservoir
• Extremely low maintenance:
Very long life time detector with electrolyte, up to 10 years
Low gas consumption, can be reduced in option
More than 10 years data storage : full chromatogram
No cylinders required thanks to internal calibration tube and gas generators
• Automatic control with process device
• Intelligents system with tunable and interactive alarm levels
• Powerful VISTACHROM Chromatotec® software: Remote monitoring & injec -
tion control
Full traceability with on board archiving of results and chromato grams
QC Set up and control of threshold alarms
Data export by MODBUS / 4-20 mA / 0-10 V
Time stamp results
Options:
• Multiple stream selector (up to 32 streams with one analyser)
• Explosion proof version Exp or Exd for ATEX, IECEx zone 1 and 2 group IIC T4
and also for CSA C1D2 group B , C & D T4
• Calculation modules (Average / Statistics / Odor index and more)
• Automatic data transfert through: Module for 4 outputs 4-20 mA (with 0 mA for
instrument default) / 0 - 10 V / MODBUS RTU or TCPI IP or MGS1
• Nitrogen or air generator for safe and hasardous area
• 24 V DC power supply
• Electric selection valve to reduce air consumption
• Liquid injection valve from LPG up to condensates
• High concentration injection valve up to 5%
• Wall mounted box XXX934
• Liquid injection valve for LPG analysis
• Touch screen on the front panel for Exp version (only ATEX)
• External cylinder inlet for automatic calibration from external cylinder
• MFC for multipoint calibration from internal CALIB and/or from cylinder
• Zero method
Product technical specifications:
Compounds Analysed: • THT – TetraHydroThiophene and TBM Ter Buthyl Mercaptan
Detection Limit: • ppm Model – 1 mg/m3• ppb Model – 0.3 mg/m3
Detection Range: • ppm model - 1 to 50 mg/m3 • ppb model - 0.3 to 3.0mg/ m3 (Ranges adjustable depending on Application)
Relative Standard Deviation: • RSD < 2 % on concentration over 48H• RSD < 0.6% on retention time over 48H
Cycle Time : • THT and TBM 180s (for one stream)• THT and TBM 240s to 300s (for multi stream)
Supervisor: • Embeded computer Windows® based with LCD display • 128 GB of Hardware storage on SSD memory
Linearity: • > 0.995 for all compounds
Communication: • MODBUS RTU included in standard • Ethernet, remote control
Gas supply: • Carrier Gas: N2 (3 bars): 10 ml/min• Internal calibration: 50 ml/min (if selected)• Sample inlet 1 bar (160 ml/min)• Pneumatic valve 90 ml/commutation
Power supply: • Main: 230V / 60Hz or 115V / 50Hz• In case of power loss, the isntrument will restart auto - matically
Electrical consumption: • Mean: 150 VA
Dimensions and weight:
To order:
THT MEDOR ®
inbuilt computer - 5UTHT MEDOR Exp ATEX Z2THT MEDOR Exp ATEX/IECExTHT MEDOR Exd ATEX Z1 THT MEDOR Exd IECEx Z1
Model:M31022
M31022-ATEX-Z2M31022-ATEX-Z1M31022-ATEX-Z1-ExdM31022-IECEx-Z1-Exd
• Rack: 19 ’’ - (5U) • Height: 222mm• Width: 482mm• Depth: 600mm• Net weight: 22Kg
Exp version: • Height: 800mm • Width: 600mm • Depth: 320mm • Net weight: 40Kg
\225