brochure du système de surveillance en ligne des composés soufrés airmo S
brochure sur le système de surveillance airmo S pour les composés soufrés

Contenu du document
TSP C52 online gas analyzer experts
Gas analyzer: GC 866
airmo S
Online monitoring of sulfur compounds by auto GC/FPD
Sulfur Specific Detector (from ppt to ppb)
Model: C52022-Trap (5U)
Compounds targeted:
- Standard Version: CS2
- Mercaptans (Methyl-SH / Ethyl-SH...)
- Sulfides (DMS / DMDS / DES…)
- Upon Request: Isopropyl-SH / Terbutyl -SH
Main Markets:
- Ambient Air Monitoring
- Waste Water Treatment Plant
- Gas odorisation & deodorisation
- Impurities in Pure Gas (CO2, CH4…)
Chromatotec® is specialized in VOC, sulfur and permanent gases analysis at trace and ultra-trace levels (ppm, ppb, ppt).
Updated: Jan 2019
airmo S - Description:
airmo S is a fully automatic isothermal gas Chromatograph for the analysis & monitoring of sulfur compounds with a Sulfur Specific Detector. This solution is specific for applications where low sensitivity on sulfurs must be reached. This auto GC uses a valve with 1 sample trap, and metallic capillary columns.
Product technical specifications:
Compounds analysed:
- Specific sulfur compounds analysis: Me-SH, Et-SH, DMS, DES, DMDS, CS2 …
- Options: n-propyl-SH, 2-butyl-SH, Isopropyl-SH, Terbutyl-SH
Detection limits with trap:
- 0,1 ppb double Sulfur Compounds like DMDS, CS2 etc...
- 0,2 ppb single Sulfur Compounds (MM, DMS etc..)
Detection range (selectable ppm / ppb):
- 0,2 to 10 ppb (amplification 2)
- 1 to 40 ppb (amplification 1)
Relative Standard Deviation:
- RSD < 5% on concentration over 24hrs
- RSD < 1% on Retention Time over 24hrs
Data Management:
- Full storage of chromatograms & results
- All analysed dates & times stamped individually
Cycle Times:
- 10 minutes
Gas Supply:
- Carrier Gas - N2 recommended / Air possible 3 bar (5ml/min) 1/8’’
- Sample Inlet -1 Bar or ambient pressure (airmopump)
- Sampling dryer: 150-200 ml/min of dry air
- Detector - H2 at 2 Bar (70 ml/min) 1/8’’
- Air at 3 bar (80 ml/min) 1/8’’
Power Supply:
- Main: (230V / 50Hz) or (115V / 60Hz)
- Battery: 24V (as option)
- Consumption: 250W (+50W for computer)
Dimensions and Weight:
- Rack: 482 mm (19’’)
- Height: 177,8 mm (4U) or 222 mm (5U)
- Depth: 660mm
- Weight: 22 kg (With integrated computer)
VISTACHROM® software:
The software developed by Chromatotec® allows:
- Remote monitoring
- Full traceability through archiving of results and QC
- Set up and control of threshold alarms
- Export of data MODBUS / MGS1 / 4-20mA / 0-10V
- Windows 7
Options:
- Automatic data transfer through:
- Modbus or MSG1 communication protocol
- Analog 4-20mA or 0-10V output
- Hydrogen Generator
- Zero Air Generator
- Multiple stream analysis with Multiplexer
- Dilution system
- Heated lines
- N2 Generator
Chromatotec® is continuously improving its products, therefore these specifications are subject to change without notice.
Contact: sales@chromatotec.com
Locations:
- North America: Houston - USA
- Europe: Bordeaux - France
- Asia: Beijing - China