brochure de l'analyseur de gaz airmoVOC C6-C12
présentation de l'analyseur de gaz airmoVOC C6-C12 et de ses spécifications techniques

Contenu du document
TSP A21
Online Gas Analyzer Experts
Gas Analyzer GC 866
airmoVOC C6-C12
BTEX included
Analysis of up to 53 compounds from Naphtalene C6 to C12 and halogen compounds (TO14) or (PAMS).
- CHCL3
- Styrene
Certified
EN 14662-3
EN 15267-1
EN 15267-2
2015
Model: A21022
Environment:
- Urban/Non-urban area pollution control
- Indoor measurements
- BTEX / PAMS / CE analysis
- Plant / process emissions
Process:
- Industrial Hygiene
- Fence line monitoring
Other applications:
- Wastewater plant, Purge and trap (method 502-2 or 524)
- Ambient air control (PAMS and TO14)
- CCL4
- Tri-methylbenzene
MTBE
Selected by US EPA 1996 2006 2010
Chromatotec® is specialised in VOC, Sulfur and permanent gases analysis at trace and ultra trace levels (ppm, ppb, ppt).
Please visit our website for more details.
Updated: May 2019
WWW.CHROMATOTEC.COM
airmoVOC C6-C12
BTEX included
Analysis of up to 53 compounds from C6 to C12 and halogen compounds (TO14) or (PAMS).
Principle:
The airmoVOC C6-C12 uses a valve with 1 sample trap, and a metallic capillary column.
- Miniaturization, sensitivity, mobility and flexibility are its main features.
Everything from the sample port up to the data storage is integrated in a 19’’-rack 5U:
- Uninterrupted sampling with pre-concentration on 1 absorbent tube
- Gas chromatograph with 0.2 mm ID metallic column and programmable temperature gradient oven and pressure / flow control of the carrier gas by piezo-valve
Before delivery, the analyser is tested for one week by our quality control department. The Vistachrom software enables the user to visualize and store data on a PC. Furthermore, it enables the user to recalculate, calibrate the instrument, export data, and set up measurement.
The software allows the calculation of retention time, area, mass or concentration profiles.
Results:
- Data storage
- MODBUS / JBUS communication protocol (option)
Cycle time:
- 15 min, 30 min, 40 min, 60 min
Gas supply:
- H2 (FID and carrier gas): 30 ml/min (inlet 2 bars; 1/16’’ swagelock)
- Air (FID): 180 ml/min (inlet 3 bars; 1/8’’ swagelock)
- Sample inlet (vacuum pump) 1/4’’ swagelock
Sample volume:
- 30 to 700 ml (programmable)
Power supply:
- Main: 230 V / 115 V or 50 Hz / 60 Hz
- Battery: 24 V (option)
Electrical consumption:
- Mean: 150 VA, Peak 360 VA
Dimensions and weight:
- Rack: 19’’ - (5U)
- Height: 222 mm
- Width: 482 mm
- Depth: 600 mm
- Net Weight: 22 kg
Options:
- On-line results are transmitted via: MODBUS / JBUS or MGS1 communication protocol
- AirmoVOC Expert 1 ppt
- Automatic validation and calibration with internal CALIB
- 24 V power supply
- Hydrogen and zero air generator for transportable analysers
- Multiplexer: 2 to 32
- Purge module to extract VOC from water for online VOC in water analysis
- Internal or external multipoint calibration and zero with CALIB MFC, XXXCYL MFC, airmoCAL MFC or airmoCAL D
- Up to C16 with airmoVOC C6C16
To order:
Model: A21022
5U inbuilt computer
Chromatotec® is continuously improving its products, therefore these specifications are subject to change without notice.
To contact us: sales@chromatotec.com