Document
tsp_a11_airmoVOC_C2C6
Contenu du document
ONLINE GAS ANALYZER EXPERTS
WWW.CHROMATOTEC.COM
airmoV O C C2-C6
Designed for analysis + monitoring of “light” hydrocarbons.
It is used for the measurement of volatile hydrocarbon in the range
of C2 to C6 i.e. from Ethane through 1,3-Butadiene up to Benzene
(and other C6 compounds).
TSP A11
Chromatotec ® is specialised in VOC, Sulfur and permanent gases analysis at trace and ultra trace levels (ppm, ppb, ppt). Please visit our website for more details.
GAS ANALYZER GC 866
1996 2006 2010 Selected by US EPA
Model: A11000
Environment:
Urban / Non urban area pollution control
Indoor measurements
BTEX / PAMS / CE analysis
Plant / process emissions
Toxicity:
Benzene, 1,3-butadiene
VOC screening of CO2 quality for the food and beverage industry
Process:
Industrial Hygiene
Fence line monitoring
Acetaldehyde/benzene
Updated: May 2019
1,3-butadiene
Pentenes
Ethane
Acetylene
Butenes
WWW.CHROMATOTEC.COM
airmoV O C C2-C6
Designed for analysis + monitoring of “light” hydrocarbons.
It is used for the measurement of volatile hydrocarbon in the
range of C2 to C6 i.e. from Ethane through 1,3-Butadiene up
to Benzene (and other C6 compounds).
To contact us: sales@chromatotec.com
NORTH AMERICAHouston - USA EUROPEBordeaux - FRANCE
ASIA Beijing - CHINA
Chromatotec ® is continuously improving its products, therefore these specifications are subject to change without notice
Example of analysed VOC’s PAMS Photochemical Assessment Monitoring Stations USA EUR
All VOC below can be analysed 20/55AIRS FORMAT * 17/30
Ethane C2 43202 X
Ethylène/Ethene 43203 X
Acéthylène/Ethyne 43206 X
Propane C3 43204 X
Propyléne/Propène 43205 X
iso-butane (2-methyl propane) 43214 X
N-butane C4 43212 X
1-butène 43280 X
Iso-butene (2-methyl propene) 43215
Trans-2-butène 43216 X
Propyne
Cis-2-butène 43217 X
1,3 butadiène X
Cyclopentane 43242
iso-pentane (2-méthyl butane) 43221 X
N-pentane C5 43220 X
1-pentène 43224 X
Trans-2-pentène 43226 X
Cis-2-pentène 43227 X
Principle:
The instrument uses a 6-port valve with a single sorbent trap, and a met\
allic
capillary column.
It has a minimum detection level as low as 15 ppt (i.e. 1,3-Butadiene ) in
ambient air, and analyses up to 32 compounds during a single analysis.
The airmo VOC C2 – C6 uses a thermoelectric cooling system to control
the temperature of the sample trap when required, for example for the an\
aly -
sis of Ethyne .
Miniaturization, sensitivity, mobility and flexibility are its main features.
Everything from the sample port up to the data storage is integrated in \
a 19"-
rack 4U.
Programmed gradient temperature of the oven and pressure/flow control of
the carrier gas by the piezo-valve .
Before delivery the analyser is tested for one week by our quality contr\
ol
department.The Vistachrom software enables the user to view and store data
on a PC. It provides user friendly utilities to recalculate, calibrate a\
nd export
data and to configure the measurement. The software allows the calculation
of retention time, area, mass and/or concentration profiles.
Options:
• On-line results are transmitted via a MODBUS / JBUS or MGS1
communication protocol
• Analog output 4-20 mA or 0-10 V
• Automatic validation / calibration
• 24 V power supply
• Hydrogen and zero air generator for transportable analysers.
• Multiple Stream selector (2 to 6)
Product technical specifications:
Light COV analysis:
Detection limit:
• 15 ppt for 1,3-Butadiene or 33 ng/m 3
Detection range: • 0.5 to 100 PPB/amplification3 in standard
Relative Standard Deviation:
• < 0.3 %over 48h (RT)• < 2 % over 48 h (Conc.)
Results:
• Data storage• 4-20mA current output (option)• MODBUS / JBUS or MGS1 communication protocol (option)
Cycle time:
• 30 min as standard (20 min. optional)
Gas supply:
• H2 (FID and carrier gas): 30 ml/min (inlet 2 bars; 1/16" swagelock)• Air (FID): 180 ml/min (inlet 3 bars; 1/8" swagelock)• Sample inlet (vacuum pump) 1/4" swagelock
Sample volume:
• 20 to 240 ml (programmable)
Power supply:
• Main: 230V / 115V or 50 Hz / 60Hz• Battery: 24V (option)
Electrical consumption:
• Mean: 150 VA, peak 360 VA
Dimensions and weight:
• Rack: 19" - (4U)• Height: 180mm • Width: 482mm• Depth: 600mm• Net weight : 17 Kg
To order:airmoVOC C2-C6 (4U) (with internal cooling)Needs a 5U supervisorSupervisor (5U)Chromatotec ® computer 5U, LCD display, Vistachrom software, 2 x RS232
Model:A11000
XXX015
Entreprise(s) concernée(s) :
Produit(s) concerné(s) :
Date d'upload du document :
vendredi 19 mars 2021