TRACE Narwhal RS1 Datasheet
Contenu du document
Uniquely specialized to be the most adept of its kind, this colorimetric
analyzer is engineered at the intersection of precision and economy.
Every detail has been designed to perfect performance and user
experience. There’s simply nothing else like NARWHAL ™ on the market.
NARWHAL automates time-consuming lab-based tests for an array of water quality applications. Setting up is simple, and
the 7” intuitive touch screen allows for easy customization and data monitoring – including real-time indication of process
conditions. With faster turnaround, higher testing volume, and increased precision and reproducability, NARWHAL makes a
splash both in reducing human error and increasing productivity in the lab.
The RS1 performs fully automated colorimetric
measurements in a process setting utilizing
up to three reagents.
7” intuitive touch screen display with easy-to-use
software allows users to calibrate and view data.
Automatic 2-point calibration maintained with
self-referencing feature. The interval between
&Yx% A?( I??6b`
Self-cleaning design and long life LED minimize
required maintenance.
Theory of Operation
Features & Bene? ts
2u?e?% A?F0
valve and pump for ease of maintenance and
high-precision measurements.
Low reagent and sample usage (ex: optional 2.5 L
reagents for 3 months silica).
Multitude of diagnositc features that alert users
of process upsets.
Standard data outputs include MODBUS, 4-20mA,
USB to CST Software, and removable SD card.
The RS1 is designed to perform fully automated
colorimetric measurements and deliver the product
of the chemical reaction to an analysis cell in a process
$bY?h% A?$p?Q2??
of sample from a stream and mixes it with up to three
reagents in succession. After each reagent addition,
a mixing cycle is performed followed by a variable
reaction delay.
Once the reagent addition process is complete,
16e% A???(huI?
where the compound of interest can be determined
via an absorbance measurement. The RS1 is designed
to be mounted near the pipeline containing the sample
of interest which is retreived from the pipeline via a fast
loop. The RS1 also utilizes a grab sample chamber to
make analyzing small sample volumes quick and easy.
531 AXMINISTER DR | FENTON, MO 63026 | 636.305.0666 | SALES@CUSTOMSENSORS.COM | CUSTOMSENSORS.COM
DIMENSIONS:42 x 9 x 8”
7 ” T O U C H DISPLAY
SAMPLE OUTLET
SAMPLE INLET
WASTE
REAGENTS / CALIBRATIONSOLUTION
GRABSAMPLE
SYRINGE PUMP
MEASUREMENT CELL
SAMPLE HEATER
LED LIGHT SOURCE
PHOTOMETER
ROTARY VALVE
531 AXMINISTER DR | FENTON, MO 63026 | 636.305.0666 | SALES@CUSTOMSENSORS.COM | CUSTOMSENSORS.COM
___________________________________________________________________________________
_______________________________________________________________________________
TRACE Analysis Sarl – 548, Chemin de Simandre, 38850 Villages du Lac de Paladru, France - R.C.S. Vienne 843 920 356
Entreprise(s) concernée(s) :
Produit(s) concerné(s) :
Question(s) liée(s) :
Date d'upload du document :
vendredi 20 novembre 2020