Document
TP 3005 English (Version 2.1)
Contenu du document
Operating Instructions
Peristaltic Pump TP 3005
I
Index of contents
Index of figures……………………………………………………………II
Introduction………………………………………………………………..2
Security advices & danger warnings………………………………….3
Scope of delivery………………………………………………………….4
Technical description………………………………………………….…5
Installation………………………………………………………………….6
Changing of tube………………………………………………………….8
II
Index of figures
Figure 1: TP 3005 with AC motor ..................................................... 1
Figure 2: TP 3005 with AC motor ..................................................... 6
Figure 3: TP 3005 with DC motor ..................................................... 7
Figure 5: Dimensions of the TP 3005 with AC motor ................... 9
Figure 6: Dimensions of the TP 3005 with DC motor ................. 10
1
Figure 1: TP 3005 with AC motor
2
Introduction
Dear customer,
We would like to congratulate you for the acquisiti
on of this product and to thank you
for the trust in our company.
The TP 3005 is a quality product on the state of th e art.
The demand of Thölen Pumpen GmbH is highest quality at top price. It is our target
to improve our products continually. If you have an y ideas or requests for the
improvement of one of our products, we are looking forward to your constructive
suggestions.
3
Security advices & danger warnings
Please note:
In case of damage which will be caused by the nonob servance of the
operating instructions the warranty voids! We assum e no liability for
consequential damage and for damage to person & pro perty caused by
inappropriate operation or nonobservance of the sec urity devices!
Attention! – Shaded pole motor
The AC Motors of the TP 3005 are shaded pole motors and they are not suitable
for continuous running! The pumps with shaded pole motor are only permitted
to run for maximum 15 minutes. The interval to the next operation should be at
minimum 30 minutes.
Because of security and approval reasons unapprove d rebuilding or modifications
of the unit are inadmissible.
It is only allowed to use the unit in a dry enviro nment.
To avoid damages of the unit only tubes permitted by Thölen Pumpen GmbH are
to be used.
The installation of the unit is to be carried out only by authorized technical staff.
Repairs are also to be carried out only by authori zed technical staff.
The operation in explosive environment is not allo wed.
The pump should never transport against a closed d ischarge line (danger of tube
breakage).
4
Scope of delivery
The delivery contains the TP 3005 including an asse
mbled tube (that is a piece of
tube cut in the correct length with two tube connec tors), if necessary with a tube
lubricant.
Control of transport damages
Please control the equipment regarding intactness b efore assembling the pump. In
case of finding transport damage contrary to expect ations, please contact us
immediately.
5
Technical description
Warranty regulation
The TP 3005 has been manufactured according to high quality guidelines. Because of the
warranty regulation of the Thölen Pumpen GmbH we gi ve a warranty of 1 year for this unit.
The condition therefore is the running of the equip ment according to these operation
instructions.
Wear parts (i.e. tube) are excluded from the warran ty.
Technical data
Flow rate: depending on tube up to 812 ml/min
Dimensions without drive: 66 x 85,6 x 34,2 mm
Dimensions with motor: 66 x 100,9 x 108,6 mm (varie d depending on drive)
Weight: DC Motor: 0,6 kg
AC Motor: approx.1,5 kg
Pump head only: 0,095 kg
Nominal voltage: 12 V DC, 24V DC, 24V AC, 110 V AC, 230V AC
Current consumption nominal: 200 to 900 mA (DC moto r)
Attention! – Shaded pole motor
The AC Motors of the TP 3005 are shaded pole motors and they are not suitable for
continuous running! The pumps with shaded pole motor are only permitted to run for
maximum 15 minutes. The interval to the next operation should be at minimum 30 minutes.
6
Installation
The pump will be delivered alternatively with a DC
motor or with an AC motor. Both
versions are illustrated below.
Figure 2: TP 3005 with AC motor
7
Figure 3: TP 3005 with DC motor
The pump can be the mounted into a casing. Here the motor will be installed from
inside and the pump head from outside onto the hous ing. But in this case the wall
size of the housing should not exceed 1,5 mm becaus e with the wall of the housing
the relative strength between motor and pump will b e modified which is of
disadvantage for the running of the pump and could lead in extreme case to the
breakdown of the pump.
8
Changing of tube
First of all switch off the mains supply to change
the tube. The cover of the TP 3005
is fixed to the mounting plate with three M4x8 scre ws. You have to remove them to
change the tube.
Now remove the broken tube completely.
After removing the broken tube, clean the head care fully. If necessary, water can be
used for cleaning. Do not use alcohol or similar su bstances for cleaning because
residua of these substances can pollute the new tub e.
After cleaning the pump head, the new tube can be i nserted. Tubes for this pump will
be delivered already assembled. You just have to at tach the new tube to the housing
cover with the aid of the tube connectors.
It is important for the insertion of the tube to no te that the tube will be inserted without
breaks between head and roller on the entirety of t he head, thus adjacent on the
inner wall, and completely crushed by the tread of the roller. The tube should overlap
neither forwards nor backwards the tread of the rol ler because leakage loss could
occur and the danger of tube breakage during the op eration is increased.
Note:
If it is important for you that the medium does not flow on the suction side or on the
discharge side out of the feed pipe, please take i. e. a suitable non-return valve on the
particular side into consideration. (The draining o f the pipes causes normally no
problems to the pump because peristaltic pumps are dry self priming pumps. Only
problems on the suction side can occur when priming if the vertical height is too high
between the pump and the tank.)
Figure 5: Dimensions of the TP 3005 with AC motor
Figure 6: Dimensions of the TP 3005 with DC motor
Address:
Thölen Pumpen GmbH
Martinistrasse 50b
47608 Geldern
Germany
Phone: +49 028 31 134998-0
Fax: +49 028 31 134998-200
Web:
www.peristalticpumps.org
Email: info@thoelen-pumpen.de
Version: 07.08.2015
Entreprise(s) concernée(s) :
Question(s) liée(s) :
Date d'upload du document :
lundi 9 mai 2022