Document
PX-375 (en) - HORIBA
Contenu du document
Continuous Particulate Monitor with X-ray Fluorescence
Continuous analysis of
particulate mass and the element
with automatic sampling.
The first step towards prevention of air polluti
In recent years there has been growing concern regarding particulate matter (PM) pollution and its affects on health.
For effective preventative measures, source appointment of PM is extremely important. Therefore, indication of PM elemental concentration is
Newly developed PX-375 enables automatic sampling, continuous online PM quantitative and qualitative analysis and rapid air pollution source
Feature
1
Continuous analysis of PM mass and the elemental concentration
by a single unit directly in the field!
t Continuous analysis of PM2.5, PM10 or TSP, mass and the elemental concentration.
Sampling and the elemental analysis time are selectable.
t Extremely compact design – 19 inch size and easy installation enables the use of the
instrument in scienti?c laboratories, ?xed and mobile air quality monitoring stations
(AQMS).
t Ideal for variety of applications: ambient air quality monitoring, indoor air quality control,
stationary pollution source appointment, etc.
t Continuous analysis provides you the bene?ts of reducing labor cost and human errors
caused by manual analysis.
Screen image (PC, tablet)
Menu bar Trend graph
File Setting Maintenance Help for PX Series
Mass Conc. (?g/m3) Mass Conc. Result
Mass analysis status
Measure 70 Past data
2015/04/27 11:00
60 PM 37.1 ?g/m3
Conc. 30.5 ?g/m3
Real time value 50 Ti 13.4 nm/m3
V 58.3 3
nm/m
Mass 30.1 40
?g Cr 88.6 3
nm/m
Mn 25.9 3
nm/m
30
Fe 72.8 3
nm/m
20 Ni 52.8 3
nm/m
Cu 20.9 3
nm/m
10
Zn 13.91 3
nm/m
Detail
As 71.2 3
nm/m
3
Element Conc. (ng/m3) nm/m
Element Conc. Sb 4.6
Elemental analysis status Pb 76.6 3
nm/m
Measure
Al 29.7 3
nm/m
30 1500 Si 22.6 3
nm/m
Remaining 300 s
S 99.9 3
nm/m
Image of ?lter K 1.2 3
nm/m
with collected sample 20 1000 Ca 31.8 3
nm/m
10 500
next
Next analysis time
2015/04/27 13:00 Latest Data
2015/04/27 12:30 month week day
04/23 04/24 04/25 04/26 04/27 04/28
Operation
on is to identify pollutant concentration in real tim
also necessary in addition to PM mass concentration.
appointment.
Feature Feature
2 3
Advanced analysis by world proven HORIBA's newly developed filter tape provides
technologies. excellent sensitivity and precise performance
t Adoption of world proven technologies: X-ray t 2 layer non-woven PTFE fabric ?lter construction prevents
?uorescence & Beta-ray attenuation. passing of PM onto the reverse side.
t Compatible with calibration curves evaluated by t Due to the extremely low-impurity concentration, the ?lter
existing scienti?c instruments (ICP-MS etc.) for PX-375 enables ultra low concentration analysis.
calibration. t Chemical background of the ?lter tape is extremely
t Safety features: User is absolutely protected by inter low. Therefore the ?lter with collected sample could be
lock. No need to appoint the particular working space used for chemical analysis by other scienti?c analytical
and person in charge for the X-ray operation. instruments. (ICP-MS etc.)
Patents
?USA Patent No.8012231
?CHINA Patent No.ZL200410032415.3
?JAPAN Patent No.4590367 TFH ?lter
Lowest Detection Limit (Example) (2?) (ng/m3) (Table 1) Detectable Elements (Table 2)
Analysis time (sec.) H Detectable Elements He
Element
100 500 1000 5000 10000 Li Be B C N O F Ne
Na Mg Al Si P S Cl Ar
S 14.7 6.6 4.6 2.1 1.5
K Ca Sc Ti V Cr Mn Fe Co Ni Cu Zn Ga Ge As Se Br Kr
Ti 11.2 5.0 3.5 1.6 1.1 Rb Sr Y Zr Nb Mo Tc Ru Rh Pd Ag Cd In Sn Sb Te I Xe
Cr 1.1 0.5 0.3 0.2 0.1 Cs Ba Hf Ta W Re Os Ir Pt Au Hg Tl Pb Bi Po At Rn
Fr Ra Rf Ha Sg Bh Hs Mt Ds Rg Cn Unt Fl Unp Lv Uus Uno
Mn 4.9 2.2 1.6 0.7 0.5
lanthanoid La Ce Pr Nd Pm Sm Eu Gd Tb Dy Ho Er Tm Yb Lu
Cu 19.4 8.7 6.1 2.7 1.9
actinoid Ac Th Pa U Np Pu Am Cm Bk Cf Es Fm Md No Lr
Zn 14.4 6.4 4.5 2.0 1.4 * ??Standard parameters, calibrated by standard calibration materials.
* For measurement of element concentration calibration by standard calibration materials is needed.
As 0.1 0.0 0.0 0.0 0.0 * Please contact separately about elements, marked as non-detectable.
Se 1.3 0.6 0.4 0.2 0.1 Related products AP-370 Series is used for con-
Ag 4.4 2.0 1.4 0.6 0.4 tinuous measurement of several
Air Pollution Monitor pollutants in ambient air. It is the
Cd 23.4 10.4 7.4 3.3 2.3
AP-370 Series best trace gas monitor and Nano
Sn 15.1 6.8 4.8 2.1 1.5 level particles monitor as well.
Hg 3.1 1.4 1.0 0.4 0.3 ? NOX ? SOX
Pb 5.3 2.4 1.7 0.7 0.5 ? CO ? THC
* LDL (?) is half of the LDL (2?) ? O3
me.
Continuous Particulate Monitor with X-ray Fluorescence
Feature Feature
4 5
Advanced stationary pollution source appointment User friendly display and operation
by analysis of particulate sample image
t Installed CMOS camera enables observation of t Easy operation and data management by PX-375
collected particulate sample on the ?lter. data logging PC with original software.
t In addition to particulate mass and elemental t Convenient trend graph enables user to check
concentration analysis, checking the color of particulate mass concentration, element concentration
particulate sample is possible. and its correlation at a glance.
Particulate mass concentration, elemental t Remote operation* using internet connection will
concentration and color – this 3-point approach
enables user to check status and acquire data without
enables more reliable stationary air pollution source
going on site.
appointment. *Devices needed for remote access and internet connection
should be prepared by customer.
t Operating cost is reduced by omission of the
vacuum pump and liquid nitrogen, usually required
for X-ray ?uorescence detector operation.
Image of ?lter
with collected sample t Power distribution function from the main unit for
necessary accessories: PC, heater, pump etc.
Air Quality Monitoring Station (AQMS) Air Quality Monitoring Station is
a facility to monitor wind speed,
Ambient Air Sampling Head Wind Speed & Direction wind direction and other weather
data, concentration of required air
PM* Sampling Head pollutants: SO2, NOX, CO, O3, THC
Temp. & Humidity and particulate matter during all
the year continuously. The measured
data could be transferred to
the local authorities and other in-
Solarimeter stitutions monitoring air pollution
in wide region.
Mobile Air Quality Monitoring
Stations are available too. Every
Monitoring Station is designed
Data Logger Air Conditioner and equipped according to cus-
PM Analyzer tomers requests and needs.
SO2 Analyzer Router
MODEM
THC Analyzer
NOx Analyzer
Calibration Unit
& CO Analyzer
Zero Gas Generator PC
(Example) O3 Analyzer
Sampling Manifold *PM: particulate matter
?Specifications ?External Dimensions(Unit: mm)
Product name Continuous Particulate Monitor with X-ray Fluorescence
Model PX-375
Measured object Particulate matter (PM10, PM2.5, TSP)
Measurement content Particulate mass concentration and element concentration
Common
Flow rate 16.7L/min
Sampling pump Linear drive system, externally installed
Filter tape None-woven PTFE fabric ?lter
Spot tape interval 20/25/50/100mm selectable
Filter tape replacement interval Approx. 1 month (In case of 100mm spot interval)
Ambient operation temperature 10?C~30?C
Relative humidity 0~80% RH noncondensing
Altitude 1000m or less 266
Power supply AC100V~240V ±10%, 50/60Hz±1%
Power consumption Approx. 400VA
430±3
External dimension 430mm(W)×550mm(D)×285mm(H) (without sampling pipe and measurement head)
Weight Approx. 40kg (Without sampling pipe and measurement head) ?19?
Data output CSV ?le (Average PM mass and elemental concentration)
External connection Ethernet TM, USB, RS-232C* (option)
*Please consult about communication and instrument composition separately.
Mass analyzer unit
Measurement method Beta-ray attenuation
PM10 US EPA Louvered PM10 Inlet
PM2.5 BGI VSCCTM Cyclone
TSP TSP Inlet
Measurement range 0~200/500/1000?g/m3
Repeatability ±2% (against reference foil value)
Span drift ±3% (24hours)
Lowest detection limit (2?) ±2?g/m3 (24hours)
Sampling and measurement cycle 0.5/1/2/3/4/6/8/12/24 hours
Element analyzer unit
Measurement method Energy dispersive X-ray spectroscopy
See Table 2 "Detectable Elements".
Detectable elements 560±3
Standard parameter is S, Ti, Cr, Mn, Ni, Cu, Zn, Pb, Al, Si, K, Ca, V, Fe, As.
Primary X-ray ?lter Automatic switching for light metals/heavy metals
* External dimensions do not include sampling pump,
Tube voltage Automatic switching for 15kV/50kV sampling pipe and measurement head.
Detector SDD (Silicon Drift Detector)
Sample image CMOS camera
Recommended EPA Method IO 3.3
Lowest detection limit (2?) See Table 1 "Lowest Detection Limit (Example)"
Measurement range Up to measurement time
Analysis time 1000s (16.6 min) as standard
100 / 200 / 500 / 1000 / 2000 / 5000 / 10000s selectable
Calibration material for X-ray
intensity for standard parameter NIST SRM 2783, other materials (option)
Internal lock system
Safety functions for X-ray Key switch
X-ray indication light
The HORIBA Group adopts IMS (Integrated Management System) which integrates Quality Management System ISO9001, Environmental Management System ISO14001,
and Occupational Health and Safety Management System OHSAS18001.
We have now integrated Business Continuity Management System ISO22301 in order to provide our products and services in a stable manner, even in emergencies.
Please read the operation manual before using this product to assure safe and proper handling of the product.
LThe specifications, appearance or other aspects of products in this catalog are subject to change without notice.
LPlease contact us with enquiries concerning further details on the products in this catalog.
LThe color of the actual products may differ from the color pictured in this catalog due to printing limitations.
LIt is strictly forbidden to copy the content of this catalog in part or in full.
LThe screen displays shown on products in this catalog have been inserted into the photographs through compositing.
LAll brand names, product names and service names in this catalog are trademarks or registered trademarks of their respective companies.
http://www.horiba.com e-mail: info@horiba.co.jp
HORIBA, Ltd. Japan HORIBA (Thailand) Ltd. Thailand HORIBA Instruments Brazil, Ltda. Brazil
Head Office East Office Head Office
2 Miyanohigashi, Kisshoin, Minami-ku, Kyoto, Japan 850 / 7 Soi Lat Krabang 30 / 5, Lat Krabang Road, Lat Krabang, Rua:Presbitero Plinio Alves de Souza, 645, Loteamento
Phone: 81 (75) 313-8121 Fax: 81 (75) 321-5725 Bangkok 10520, Thailand Polo Multivias Barirro Medeiros-Jundiai Sao Paulo
Phone: 66 (0) 2734 4434 Fax: 66 (0) 2734 4438 CEP 13.212-181 Brazil
HORIBA (China) Trading Co., Ltd. China Phone: 55 (11) 2923-5400 Fax: 55 (11) 2923-5490
Shanghai PT HORIBA Indonesia Indonesia
Unit D, 1F, Building A, Synnex International Park, 1068 West Jl. Jalur Sutera Blok 20A, No.16-17, Kel. Kunciran, Kec. Pinang HORIBA France Sarl France
Tianshan Road, Shanghai, 200335, China Tangerang-15144, Indonesia 12. Av des Tropiques Hightec Sud, F-91955 Les Ulis, France
Phone: 86 (21) 6289-6060 Fax: 86 (21) 6289-5553 Phone: 62 (21) 3044-8525 Fax: 62 (21) 3044-8521 Phone: 33 (1) 69-29-96-23 Fax: 33 (1) 69-29-95-77
Beijing
12F, Metropolis Tower, No.2, Haidian Dong 3 Street, Beijing, HORIBA India Private Limited India HORIBA UK Limited UK
100080, China Delhi Northampton
Phone: 86 (10) 8567-9966 Fax: 86 (10) 8567-9066 246, Okhla Industrial Estate, Phase 3 New Delhi-110020, India Kyoto Close Moulton Park, Northampton NN3 6FL, UK
Phone: 91 (11) 4646-5000 Fax: 91 (11) 4646-5020 Phone: 44 (1604) 542-500 Fax: 44 (1604) 542-699
HORIBA Korea Ltd. Korea Pune
10, Dogok-Ro, 6-Gil, Gangnam-Gu, Seoul-Si, 06259, Korea 502, 5th Floor, Purushottam Plaza, Baner Road, Baner, HORIBA Europe GmbH Germany
Phone: 82 (2) 753-7911 Fax: 82 (2) 756-4972 Pune-411045 India Head Office
Phone: 91 (20) 4076-6000 Fax: 91 (20) 4076-6010 Hans-Mess-Str.6 D-61440 Oberursel Germany
HORIBA Instruments (Singapore) Pte Ltd. Singapore Bangalore Phone: 49 (6172) 1396-0 Fax: 49 (6172) 1373-85
3 Changi Business Park Vista #01-01 Akzonobel House, Kamadhenu, No.17 / 1 - 32, Bannerghatta Road, Leichlingen
Singapore 486051 Audugodi Bangalore-560030 India Julius-kronenberg Str.9 D-42799 Leichlingen Germany
Phone: 65 (6) 745-8300 Fax: 65 (6) 745-8155 Phone: 91 (80) 22210071 Phone: 49 (2175) 8978-0 Fax: 49 (2175) 8978-50
HORIBA Vietnam Co., Ltd. Vietnam HORIBA Instruments Inc. USA HORIBA Czech Czech
Unit 6, 10 Floor, CMC Tower, Duy Tan Street, Dich Vong Head Office Prumyslova 1306 / 7, CZ-10200, Praha 10, Czech Republic
Hau Ward, Cau Giay District, Hanoi, Vietnam 9755 Research Drive, Irvine, CA 92618, U.S.A. Phone: 420 (2) 460-392-65
Phone: 84 (4) 3795-8552 Fax: 84 (4) 3795-8553 Phone: 1 (949) 250-4811 Fax: 1 (949) 250-0924
Alvin, TX HORIBA (Austria) GmbH Austria
5318 W.FM517 Rd, Alvin, TX 77511, U.S.A
Kaplanstrasse 5 A-3430 Tulln, Austria
Phone: 1 (281) 482- 4334 Fax: 1 (281) 614-0303
Phone: 43 (2272) 65225 Fax: 43 (2272) 65230
Bulletin:HRE-2341C Printed in Japan 1601SK33
Continuous analysis of
particulate mass and the element
with automatic sampling.
The first step towards prevention of air polluti
In recent years there has been growing concern regarding particulate matter (PM) pollution and its affects on health.
For effective preventative measures, source appointment of PM is extremely important. Therefore, indication of PM elemental concentration is
Newly developed PX-375 enables automatic sampling, continuous online PM quantitative and qualitative analysis and rapid air pollution source
Feature
1
Continuous analysis of PM mass and the elemental concentration
by a single unit directly in the field!
t Continuous analysis of PM2.5, PM10 or TSP, mass and the elemental concentration.
Sampling and the elemental analysis time are selectable.
t Extremely compact design – 19 inch size and easy installation enables the use of the
instrument in scienti?c laboratories, ?xed and mobile air quality monitoring stations
(AQMS).
t Ideal for variety of applications: ambient air quality monitoring, indoor air quality control,
stationary pollution source appointment, etc.
t Continuous analysis provides you the bene?ts of reducing labor cost and human errors
caused by manual analysis.
Screen image (PC, tablet)
Menu bar Trend graph
File Setting Maintenance Help for PX Series
Mass Conc. (?g/m3) Mass Conc. Result
Mass analysis status
Measure 70 Past data
2015/04/27 11:00
60 PM 37.1 ?g/m3
Conc. 30.5 ?g/m3
Real time value 50 Ti 13.4 nm/m3
V 58.3 3
nm/m
Mass 30.1 40
?g Cr 88.6 3
nm/m
Mn 25.9 3
nm/m
30
Fe 72.8 3
nm/m
20 Ni 52.8 3
nm/m
Cu 20.9 3
nm/m
10
Zn 13.91 3
nm/m
Detail
As 71.2 3
nm/m
3
Element Conc. (ng/m3) nm/m
Element Conc. Sb 4.6
Elemental analysis status Pb 76.6 3
nm/m
Measure
Al 29.7 3
nm/m
30 1500 Si 22.6 3
nm/m
Remaining 300 s
S 99.9 3
nm/m
Image of ?lter K 1.2 3
nm/m
with collected sample 20 1000 Ca 31.8 3
nm/m
10 500
next
Next analysis time
2015/04/27 13:00 Latest Data
2015/04/27 12:30 month week day
04/23 04/24 04/25 04/26 04/27 04/28
Operation
on is to identify pollutant concentration in real tim
also necessary in addition to PM mass concentration.
appointment.
Feature Feature
2 3
Advanced analysis by world proven HORIBA's newly developed filter tape provides
technologies. excellent sensitivity and precise performance
t Adoption of world proven technologies: X-ray t 2 layer non-woven PTFE fabric ?lter construction prevents
?uorescence & Beta-ray attenuation. passing of PM onto the reverse side.
t Compatible with calibration curves evaluated by t Due to the extremely low-impurity concentration, the ?lter
existing scienti?c instruments (ICP-MS etc.) for PX-375 enables ultra low concentration analysis.
calibration. t Chemical background of the ?lter tape is extremely
t Safety features: User is absolutely protected by inter low. Therefore the ?lter with collected sample could be
lock. No need to appoint the particular working space used for chemical analysis by other scienti?c analytical
and person in charge for the X-ray operation. instruments. (ICP-MS etc.)
Patents
?USA Patent No.8012231
?CHINA Patent No.ZL200410032415.3
?JAPAN Patent No.4590367 TFH ?lter
Lowest Detection Limit (Example) (2?) (ng/m3) (Table 1) Detectable Elements (Table 2)
Analysis time (sec.) H Detectable Elements He
Element
100 500 1000 5000 10000 Li Be B C N O F Ne
Na Mg Al Si P S Cl Ar
S 14.7 6.6 4.6 2.1 1.5
K Ca Sc Ti V Cr Mn Fe Co Ni Cu Zn Ga Ge As Se Br Kr
Ti 11.2 5.0 3.5 1.6 1.1 Rb Sr Y Zr Nb Mo Tc Ru Rh Pd Ag Cd In Sn Sb Te I Xe
Cr 1.1 0.5 0.3 0.2 0.1 Cs Ba Hf Ta W Re Os Ir Pt Au Hg Tl Pb Bi Po At Rn
Fr Ra Rf Ha Sg Bh Hs Mt Ds Rg Cn Unt Fl Unp Lv Uus Uno
Mn 4.9 2.2 1.6 0.7 0.5
lanthanoid La Ce Pr Nd Pm Sm Eu Gd Tb Dy Ho Er Tm Yb Lu
Cu 19.4 8.7 6.1 2.7 1.9
actinoid Ac Th Pa U Np Pu Am Cm Bk Cf Es Fm Md No Lr
Zn 14.4 6.4 4.5 2.0 1.4 * ??Standard parameters, calibrated by standard calibration materials.
* For measurement of element concentration calibration by standard calibration materials is needed.
As 0.1 0.0 0.0 0.0 0.0 * Please contact separately about elements, marked as non-detectable.
Se 1.3 0.6 0.4 0.2 0.1 Related products AP-370 Series is used for con-
Ag 4.4 2.0 1.4 0.6 0.4 tinuous measurement of several
Air Pollution Monitor pollutants in ambient air. It is the
Cd 23.4 10.4 7.4 3.3 2.3
AP-370 Series best trace gas monitor and Nano
Sn 15.1 6.8 4.8 2.1 1.5 level particles monitor as well.
Hg 3.1 1.4 1.0 0.4 0.3 ? NOX ? SOX
Pb 5.3 2.4 1.7 0.7 0.5 ? CO ? THC
* LDL (?) is half of the LDL (2?) ? O3
me.
Continuous Particulate Monitor with X-ray Fluorescence
Feature Feature
4 5
Advanced stationary pollution source appointment User friendly display and operation
by analysis of particulate sample image
t Installed CMOS camera enables observation of t Easy operation and data management by PX-375
collected particulate sample on the ?lter. data logging PC with original software.
t In addition to particulate mass and elemental t Convenient trend graph enables user to check
concentration analysis, checking the color of particulate mass concentration, element concentration
particulate sample is possible. and its correlation at a glance.
Particulate mass concentration, elemental t Remote operation* using internet connection will
concentration and color – this 3-point approach
enables user to check status and acquire data without
enables more reliable stationary air pollution source
going on site.
appointment. *Devices needed for remote access and internet connection
should be prepared by customer.
t Operating cost is reduced by omission of the
vacuum pump and liquid nitrogen, usually required
for X-ray ?uorescence detector operation.
Image of ?lter
with collected sample t Power distribution function from the main unit for
necessary accessories: PC, heater, pump etc.
Air Quality Monitoring Station (AQMS) Air Quality Monitoring Station is
a facility to monitor wind speed,
Ambient Air Sampling Head Wind Speed & Direction wind direction and other weather
data, concentration of required air
PM* Sampling Head pollutants: SO2, NOX, CO, O3, THC
Temp. & Humidity and particulate matter during all
the year continuously. The measured
data could be transferred to
the local authorities and other in-
Solarimeter stitutions monitoring air pollution
in wide region.
Mobile Air Quality Monitoring
Stations are available too. Every
Monitoring Station is designed
Data Logger Air Conditioner and equipped according to cus-
PM Analyzer tomers requests and needs.
SO2 Analyzer Router
MODEM
THC Analyzer
NOx Analyzer
Calibration Unit
& CO Analyzer
Zero Gas Generator PC
(Example) O3 Analyzer
Sampling Manifold *PM: particulate matter
?Specifications ?External Dimensions(Unit: mm)
Product name Continuous Particulate Monitor with X-ray Fluorescence
Model PX-375
Measured object Particulate matter (PM10, PM2.5, TSP)
Measurement content Particulate mass concentration and element concentration
Common
Flow rate 16.7L/min
Sampling pump Linear drive system, externally installed
Filter tape None-woven PTFE fabric ?lter
Spot tape interval 20/25/50/100mm selectable
Filter tape replacement interval Approx. 1 month (In case of 100mm spot interval)
Ambient operation temperature 10?C~30?C
Relative humidity 0~80% RH noncondensing
Altitude 1000m or less 266
Power supply AC100V~240V ±10%, 50/60Hz±1%
Power consumption Approx. 400VA
430±3
External dimension 430mm(W)×550mm(D)×285mm(H) (without sampling pipe and measurement head)
Weight Approx. 40kg (Without sampling pipe and measurement head) ?19?
Data output CSV ?le (Average PM mass and elemental concentration)
External connection Ethernet TM, USB, RS-232C* (option)
*Please consult about communication and instrument composition separately.
Mass analyzer unit
Measurement method Beta-ray attenuation
PM10 US EPA Louvered PM10 Inlet
PM2.5 BGI VSCCTM Cyclone
TSP TSP Inlet
Measurement range 0~200/500/1000?g/m3
Repeatability ±2% (against reference foil value)
Span drift ±3% (24hours)
Lowest detection limit (2?) ±2?g/m3 (24hours)
Sampling and measurement cycle 0.5/1/2/3/4/6/8/12/24 hours
Element analyzer unit
Measurement method Energy dispersive X-ray spectroscopy
See Table 2 "Detectable Elements".
Detectable elements 560±3
Standard parameter is S, Ti, Cr, Mn, Ni, Cu, Zn, Pb, Al, Si, K, Ca, V, Fe, As.
Primary X-ray ?lter Automatic switching for light metals/heavy metals
* External dimensions do not include sampling pump,
Tube voltage Automatic switching for 15kV/50kV sampling pipe and measurement head.
Detector SDD (Silicon Drift Detector)
Sample image CMOS camera
Recommended EPA Method IO 3.3
Lowest detection limit (2?) See Table 1 "Lowest Detection Limit (Example)"
Measurement range Up to measurement time
Analysis time 1000s (16.6 min) as standard
100 / 200 / 500 / 1000 / 2000 / 5000 / 10000s selectable
Calibration material for X-ray
intensity for standard parameter NIST SRM 2783, other materials (option)
Internal lock system
Safety functions for X-ray Key switch
X-ray indication light
The HORIBA Group adopts IMS (Integrated Management System) which integrates Quality Management System ISO9001, Environmental Management System ISO14001,
and Occupational Health and Safety Management System OHSAS18001.
We have now integrated Business Continuity Management System ISO22301 in order to provide our products and services in a stable manner, even in emergencies.
Please read the operation manual before using this product to assure safe and proper handling of the product.
LThe specifications, appearance or other aspects of products in this catalog are subject to change without notice.
LPlease contact us with enquiries concerning further details on the products in this catalog.
LThe color of the actual products may differ from the color pictured in this catalog due to printing limitations.
LIt is strictly forbidden to copy the content of this catalog in part or in full.
LThe screen displays shown on products in this catalog have been inserted into the photographs through compositing.
LAll brand names, product names and service names in this catalog are trademarks or registered trademarks of their respective companies.
http://www.horiba.com e-mail: info@horiba.co.jp
HORIBA, Ltd. Japan HORIBA (Thailand) Ltd. Thailand HORIBA Instruments Brazil, Ltda. Brazil
Head Office East Office Head Office
2 Miyanohigashi, Kisshoin, Minami-ku, Kyoto, Japan 850 / 7 Soi Lat Krabang 30 / 5, Lat Krabang Road, Lat Krabang, Rua:Presbitero Plinio Alves de Souza, 645, Loteamento
Phone: 81 (75) 313-8121 Fax: 81 (75) 321-5725 Bangkok 10520, Thailand Polo Multivias Barirro Medeiros-Jundiai Sao Paulo
Phone: 66 (0) 2734 4434 Fax: 66 (0) 2734 4438 CEP 13.212-181 Brazil
HORIBA (China) Trading Co., Ltd. China Phone: 55 (11) 2923-5400 Fax: 55 (11) 2923-5490
Shanghai PT HORIBA Indonesia Indonesia
Unit D, 1F, Building A, Synnex International Park, 1068 West Jl. Jalur Sutera Blok 20A, No.16-17, Kel. Kunciran, Kec. Pinang HORIBA France Sarl France
Tianshan Road, Shanghai, 200335, China Tangerang-15144, Indonesia 12. Av des Tropiques Hightec Sud, F-91955 Les Ulis, France
Phone: 86 (21) 6289-6060 Fax: 86 (21) 6289-5553 Phone: 62 (21) 3044-8525 Fax: 62 (21) 3044-8521 Phone: 33 (1) 69-29-96-23 Fax: 33 (1) 69-29-95-77
Beijing
12F, Metropolis Tower, No.2, Haidian Dong 3 Street, Beijing, HORIBA India Private Limited India HORIBA UK Limited UK
100080, China Delhi Northampton
Phone: 86 (10) 8567-9966 Fax: 86 (10) 8567-9066 246, Okhla Industrial Estate, Phase 3 New Delhi-110020, India Kyoto Close Moulton Park, Northampton NN3 6FL, UK
Phone: 91 (11) 4646-5000 Fax: 91 (11) 4646-5020 Phone: 44 (1604) 542-500 Fax: 44 (1604) 542-699
HORIBA Korea Ltd. Korea Pune
10, Dogok-Ro, 6-Gil, Gangnam-Gu, Seoul-Si, 06259, Korea 502, 5th Floor, Purushottam Plaza, Baner Road, Baner, HORIBA Europe GmbH Germany
Phone: 82 (2) 753-7911 Fax: 82 (2) 756-4972 Pune-411045 India Head Office
Phone: 91 (20) 4076-6000 Fax: 91 (20) 4076-6010 Hans-Mess-Str.6 D-61440 Oberursel Germany
HORIBA Instruments (Singapore) Pte Ltd. Singapore Bangalore Phone: 49 (6172) 1396-0 Fax: 49 (6172) 1373-85
3 Changi Business Park Vista #01-01 Akzonobel House, Kamadhenu, No.17 / 1 - 32, Bannerghatta Road, Leichlingen
Singapore 486051 Audugodi Bangalore-560030 India Julius-kronenberg Str.9 D-42799 Leichlingen Germany
Phone: 65 (6) 745-8300 Fax: 65 (6) 745-8155 Phone: 91 (80) 22210071 Phone: 49 (2175) 8978-0 Fax: 49 (2175) 8978-50
HORIBA Vietnam Co., Ltd. Vietnam HORIBA Instruments Inc. USA HORIBA Czech Czech
Unit 6, 10 Floor, CMC Tower, Duy Tan Street, Dich Vong Head Office Prumyslova 1306 / 7, CZ-10200, Praha 10, Czech Republic
Hau Ward, Cau Giay District, Hanoi, Vietnam 9755 Research Drive, Irvine, CA 92618, U.S.A. Phone: 420 (2) 460-392-65
Phone: 84 (4) 3795-8552 Fax: 84 (4) 3795-8553 Phone: 1 (949) 250-4811 Fax: 1 (949) 250-0924
Alvin, TX HORIBA (Austria) GmbH Austria
5318 W.FM517 Rd, Alvin, TX 77511, U.S.A
Kaplanstrasse 5 A-3430 Tulln, Austria
Phone: 1 (281) 482- 4334 Fax: 1 (281) 614-0303
Phone: 43 (2272) 65225 Fax: 43 (2272) 65230
Bulletin:HRE-2341C Printed in Japan 1601SK33
Entreprise(s) concernée(s) :
Question(s) liée(s) :
Date d'upload du document :
mercredi 26 juillet 2023