Document
MCA-100-syn-3-Portable-bullettin-1,
Contenu du document
MCA 100 Syn 3 Portable
MULTICOMPONENT ANALYZER FOR SynGAS
The MCA 100 SYN series of gas analyzers by ETG it ’s the ideal solution for biogas measurement and
industrial c ombustion applications because of their accuracy, stability, reliability, broad
measurement range, and the variety of available form factors.
Unlike other analyzers, ETG MCA 100 non -dispersive infrared (NDIR) gas analyzers measure multiple
gases in an inst rument with a single optical path platform.
Single -gas analyzers are inadequate when using methane as a biofuel because the gas often contains
large amounts of CO as a contaminant. ETG analyzers have the ability to measure CO2, CO, and O2 in
addition to methane and therefore provide the optimal combination of gases for combustion
optimization.
The enhanced optics and electronics of our NDIR analyzers have virtually eliminated zero drift after
the initial warm up period. The temperature and pressure compe nsation eliminates the major causes
of span drift in many NDIR instruments.
• Analysis CO 2, CH 4, CO, O2, H 2,
• NDIR technology for CO 2 CO and CH 4
• TCD for H 2
• Arm Processor
• Touch Screen monitor
• Ethernet, Wi -fi and USB Remo ting
• N2 and Heat value calculate by
proprietary algorithm ( standard )
Low cost ownership
• Portable version with battery pack
• Modbus, Profibus, Ethernet ( optional )
• Data downloadable on USB Pen Drive
• Cross sensitivity compensation
• Sample conditioning system ( optional )
• Additional CnHm measuring by NDIR
detector ( optional )
T90 & T 10 <20
seconds
+/- 0.5 abs
or +/ - 3.0%
rel
+/- 0.5% abs
or +/ - 3.0%
rel
0-10 %
0-20%
0 - 50%
0-100 %
0,1 % Hydrogen Thermoconduc
ibility
< 40 seconds
from
ambient to
0.15 O2
+/- 0,1% abs
or +/ - 1.5%
rel
+/- 0,1% abs
or +/ - 3.0%
rel
1.01 -25.00% 0,01% Oxygen Electro -
chemical
sensor
T90 & T 10 <10
seconds
+/-0,7%
+/- 0,1% abs
or +/ - 0.8%
rel
+/- 0,8 F.S.
+/- 0,3% abs
or +/ - 3.0%
rel
+/- 5% rel
0-50%
0.00 -16.00%
0.01 -20.00%
(up to 40%)
0,01%
0,01%
Carbon
Dioxide
Carbon
Monoxide
NDIR ( Non -
Dispersive
Infrared )
T90 & T 10 <10
seconds
+/- 0,8% +/- 1% F.S.
+/- 2% rel
+/- 1% rel
+/- 5% rel
0-100%
201 ppm -40%
40 -80%
80 -100%
0,01% Methane NDIR ( Non -
Dispersive
Infrared )
Time Precision Accuracy Range Resoluti
on
Gas Measurement
Method
IP67(1 meter submersion for 30 minutes) • Def Stan 81 -41/STANAG 4280
Case Protection
USB port ( standard ) Communications
-300 to 3.000 m ( -1.000 to 10.000 ft ) Operating Altitude
To 95% RH ( Non -condensing) Operating Humidity
0° to 70 ° C ( 32 ° to 158 ° F) Operating Temperature
30 seconds ready, 3 minutes useable, 30 minutes to full perfo rmance Warm -up Time
1 second Data Refresh Rate
Response times are specified at a sample flow rate of a 1 liter per minute
through the MCA 100 sample cell
Response Time
MCA 100 SYN MULTICOMPONENT ANALYZER FOR SYNGAS
SPECIFICATIONS
Other Version of gas Analyzers
• Wall mounting Biogas anal yzer version model 6500
• 19” Rack Mounting Biogas analyzer model MCA 100 Bio
• Multisampling system for Biogas analysis
ETG RISORSE E TECNOLOGIA
Via P. Carpignano 23
14026 Montiglio M.to (AT) ITALY
Tel. +39 0141 99.4905 Fax 99.49.71
sales@etgrisorse.com
www.analisi -biogas.com
www.etgr isorse.com
7.5 kg Weight
50 x 28 x 40 cm Mechanical dimensions
Rapid fittings 6.0 OD 4.0 ID Pneumatic connection
from 100 to 240 Vac 47 -63 Hz External Electrical supply
Zero & span user selecta ble. Calibration
Touch Screen 5.7 ” Resistive type Monitor
12 – 24 Vcc with Internal Charger and light charge indicator Battery
MCA 100 SYN Portable MULTICOMPONENT ANALYZER FOR SYNGAS
Bargraph and digital value Trend and digital value
USER INTERFACE OVERVIEW
All the ETG MCA 100 and 6500 series for Syngas have
Remote Support and Remote Access
? File transfer
? Data monitoring by your PC , tablet and
smartphone
? Software update
Entreprise(s) concernée(s) :
Produit(s) concerné(s) :
Date d'upload du document :
mardi 28 juin 2022