Document
datasheet-etg6500
Contenu du document
ETG 6500 TOP
MULTICOMPONENT ANALYZER FOR BIOGAS
The ETG 6500 series of gas analyzers by ETG it ’s the ideal solution for biogas measurement and
industrial combust ion applications because of their accuracy, stability, reliability, broad
measurement range, and the variety of available form factors.
Unlike other analyzers, ETG 6500 non-dispersive infrared (NDIR) gas analyzers measure multiple
gases in an instrument w ith a single optical path platform.
Single -gas analyzers are inadequate when using methane as a biofuel because the gas often contains
large amounts of CO as a contaminant. ETG analyzers have the ability to measure CO2, CO, and O2 in
addition to methane and therefore provide the optimal combination of gases for combustion
optimization.
The enhanced optics and electronics of our NDIR analyzers have virtually eliminated zero drift after
the initial warm up period. The temperature and pressure compensation e liminates the major causes
of span drift in many NDIR instruments.
• Analysis of CO 2, CH 4, O 2, H 2S
• NDIR technology for CO 2 and CH 4
•
Automatic air purge for long life H 2S
cell
• Arm Processor
• Touch Screen monitor
• Ethernet and USB Remonting
• Analog & Digital Signal Output
• Low cost ownership
• 19 “ Rack mounting or Wall mounting
version
• Modbus, Profibus, Ethernet ( optional)
• Autozero
• Data downloadable on SD Card
T9 0 & T 10 <30
seconds
+/- 3.0% rel
+/- 3.0% rel 0-2000 ppm
0-5000 ppm
1 ppm Hydrogen
Sulfide
Electro -
chemical
sensor
< 3 0 seconds
from
ambient to
0.15 O2
+/- 0,1% abs
or +/- 1.5%
rel
+/- 0,1% abs
or +/ - 3.0%
rel
0-25.00% 0,01% Oxygen Elec tro-
chemical
sensor
T90 & T 10 <10
seconds
+/-0,7%
+/- 0,1% abs
or +/ - 0.8%
rel
+/- 0,8 F.S.
+/ - 0,3% abs
or +/ - 3.0%
rel
+/ - 5% rel
0-50%
0,01% Carbon
Dioxide
NDIR ( Non -
Dispersive
Infrared )
T90 & T 10 <10
seconds
+/- 0,8% +/- 1% F.S.
+/- 2% rel
+/ - 1% rel
+/- 5% rel
0-100%
0,01% Methane NDIR ( Non -
Dispersive
Infrared )
Time Precision Accuracy Range Resoluti
on
Gas Measurement
Method
4-20 ma for each measured compound Analog Signal Output
Ethernet – Profibus – Modbus and o thers on request Communications (optional)
-300 to 3.000 m ( -1.000 to 10.000 ft ) Operating Altitude
To 95% RH ( Non -condensing) Operating Humidity
-10 °C to 70 ° C ( 32 ° to 158 ° F) Operating Temperature
30 seconds ready,3 minutes useable,30 minutes to full performance Warm -up Time
1 second Data Refresh Rate
Response times are specified at a sample flow rate of a 1 liter per minute
through the sample cell
Response Time
ETG6500 TOP MULTICOMPONENT ANALYZER FOR BIOGAS
SPECIFICATIONS
Other Version of Biogas Analyzers
• Rack Mount Bioga s analyzer version model
MCA100BIO
• Porta ble Biogas analyzer model MCA 100 Bio P
ETG RISORSE E TECNOLOGIA
Via Baione 2/K
10034 Chivasso (TO ) ITALY
Tel. +39 011 19270890
sales@etgrisorse.com
www.analisi -biogas.com
ww w.etgrisorse.com
15.75 kG Weight
850 x 900 x 3 50 mm Mechanical dimensions
6.0 OD 4.0 ID Pneumatic connection
from 100 to 240 Vac 47 -63 Hz Electrical supply
Zero & span user selectable. Automa tic calibration ( optional) Calibration
Touch Screen 5.7 ” Resistive type Monitor
Configurable for gas concentration, analyzer fault, high temperature , etc.. Digital Output
ETG6500 MULTICOMPONENT ANALYZER FOR BIOGAS
Mechanical Dimensions Overview User Monitor Interface
Bargraph and digital value Trend and digital value
All the ETG M CA 100 and 6500
series for Biogas have Remote
Support and Remote Access
• File transfer
• Data monitoring by your PC ,
tablet smartphone
• Software update
Entreprise(s) concernée(s) :
Produit(s) concerné(s) :
Date d'upload du document :
mardi 28 juin 2022